K2 Uptime monitoring

Area
K — Observability
Audience
operator
Kind
feature
Status
accepted
Maturity
planned
Labels
observability, verification
Requires
B5
Relates to
G7

The feature in the specification · Read at

Requirements

  1. K2-R1acceptedMUST

    Uptime monitoring MUST use an open-source, self-hostable monitor, and MUST NOT depend on a hosted uptime service.

    locked by
    0.23.0 open
  2. K2-R2acceptedMUST

    The monitor MUST be independent of lemonfiber's own health path, so a failure in the tool's reporting does not blind or falsify uptime coverage.

    locked by
    0.23.0 open
  3. K2-R3acceptedMUST

    Every critical service MUST have a live monitor, and every household-facing entry point MUST have one.

    locked by
    0.23.0 open
  4. K2-R4acceptedMUST

    Jobs expected to run on a schedule MUST be watched by heartbeat checks, and a missed check-in MUST itself raise an alarm.

    locked by
    0.23.0 open
  5. K2-R5acceptedMUST

    The tool MUST assert that each critical service and entry point has a monitor that is actively checking, not merely defined.

    locked by
    0.23.0 open
  6. K2-R6acceptedMUST

    The tool MUST assert that a deliberately induced failure is detected by the monitor and surfaced.

    locked by
    0.23.0 open
  7. K2-R7acceptedMUST

    Where the monitor lacks a stable configuration API, the tool MUST provision it through a supported mechanism and MUST state the limitation rather than implying an API exists.

    locked by
    0.23.0 open
  8. K2-R8acceptedMUST

    An unreachable monitor MUST be reported as blind coverage and MUST NOT be rendered as all-clear.

    locked by
    0.23.0 open
  9. K2-R9acceptedMUST

    A monitored target MUST fail consistently before alarming, so a single slow response does not raise a false positive.

    locked by
    0.23.0 open
  10. K2-R10acceptedMUST

    An intentionally stopped service MUST be treated as expected-down and MUST NOT raise an outage alarm.

    locked by
    0.23.0 open
  11. K2-R11acceptedMUST

    Alert routing MUST be reconciled with the stack's notifications (B5) so a single event does not produce duplicate alerts.

    locked by
    0.23.0 open
  12. K2-R12acceptedMUST

    An entry point MUST be monitored over the path the household actually uses, and internal reachability MUST NOT be reported as household reachability.

    locked by
    0.23.0 open
  13. K2-R13acceptedMUST

    An alert that could not be delivered MUST be surfaced as undelivered rather than recorded as delivered.

    locked by
    0.23.0 open
  14. K2-R14acceptedMUST

    Provisioning monitors and running the detection proof MUST each be reachable non-interactively.

    locked by
    0.23.0 open